What winter here actually asks of a heat pump
Your heat runs eight months a year here, October through May, and the overnight low averages 23°F across the worst of it. That number matters because a standard heat pump starts losing ground below 40°F and often needs backup heat below about 35°F. Your winter average sits below both marks. This isn't a county with a few cold snaps to plan around. Cold is the normal condition the system has to work in.
About 115 nights a year here drop to freezing or below, roughly half the nights across the whole heating season. On those nights a standard heat pump is putting out less than its rated capacity, not more. Only about one night a year reaches 0°F, so the deep cold is rare. The ordinary cold, the kind that shows up on half your winter nights, is the one that matters more for sizing and backup heat.
None of this rules out a heat pump. It means the unit has to be chosen for 23°F nights, not for a mild-climate average, and that backup heat is part of the system here rather than a rare exception. A cold-climate model changes this math: to earn that label a heat pump has to hold at least 70 percent of its rated output at 5°F and still produce 1.75 units of heat per unit of electricity there, verified by outside testing. In field tests of prototype cold-climate units, backup heat covered only a small share of the heat needed between 0°F and 35°F, and running on backup alone was rare even above 0°F. A standard heat pump and a cold-climate heat pump are not the same purchase in this county.