Will a heat pump keep up on the coldest nights here
Winter is the long season in Montgomery County. Heat runs seven months, October through April, against four months of cooling. Whatever you install is mostly a heating system that also happens to cool, so the question is how it handles January, not July.
The overnight low here averages 25°F across December, January and February, and it drops to freezing or below on about 115 nights a year, more than half the nights in the heating season. A standard heat pump starts losing ground before it even gets that cold. Below 40°F its heat output falls short of its rating. Below about 35°F it often needs backup heat to make up the difference. Every one of those 115 freezing nights falls under both marks. The average winter night here does too.
That does not mean a heat pump quits. Cold-climate models are built and tested for this. To earn the ENERGY STAR Cold Climate label, a heat pump has to keep at least 70 percent of its 47°F capacity at 5°F, and still produce 1.75 units of heat for every unit of electricity at that temperature, checked by outside testing. A two-winter field test of prototype cold-climate heat pumps in real homes found backup heat carried only a small share of the load between 0°F and 35°F, and the system ran on backup alone only rarely, even above 0°F. The nights that actually reach 0°F here are rare too, about one a year.
So a cold-climate heat pump can carry a house through a Montgomery County winter. A standard heat pump will lean on backup heat more often than you would like, because the nights it needs that backup are most of the season, not the exception.