Can a heat pump keep up with winter here
Winter here is the real question, because heat runs eight months a year in Armstrong County, October through May, and cooling only covers three. Whatever you buy will spend most of its life heating this house, not cooling it.
The average overnight low across December, January and February is 21°F. That's below the 40°F mark where a standard heat pump starts falling short of its rated output, and below the 35°F mark where it often needs backup heat to make up the difference. About 140 nights a year here drop to freezing or below, and every one of those nights is under both marks.
That doesn't mean a heat pump quits. Most of those 140 cold nights sit between freezing and the teens, not down at 0°F, and only about 5 nights a year reach that mark. A field test of cold-climate heat pumps running in occupied homes over two winters found backup heat carried only a small share of the load between 0°F and 35°F, and the units rarely ran on backup alone unless it was at or below 0°F. If you go with a heat pump, look for one carrying the ENERGY STAR Cold Climate mark. To earn it, a heat pump has to deliver at least 1.75 units of heat per unit of electricity at 5°F and hold onto 70 percent of its 47°F capacity at that temperature, verified by outside testing, not the manufacturer's own numbers.
A standard heat pump built to the federal minimum will lean on backup heat far more than that on a county with 140 freezing nights a year. A cold-climate model closes most of that gap. A gas furnace never has the question in the first place, because its output doesn't depend on how cold it is outside.